產(chǎn)品名稱:automatic balancing large-capacity centrifuge

產(chǎn)品型號(hào):SG-853

更新時(shí)間:2019-05-05

廠商性質(zhì):生產(chǎn)廠家

訪問次數(shù):2886

產(chǎn)品報(bào)價(jià):

產(chǎn)品特點(diǎn):SG-853 automatic balancing large-capacity centrifuge is the company according to the user experience,Carefully design and development of a new generation of centrifuges products

產(chǎn)品詳細(xì)資料:

SG-853 automatic balancing large-capacity centrifuge is  the company  according to the user experience,Carefully design and development of a new generation of centrifuges products, and compared to similar products with higher quality advantage:apply to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use. is applicable to all types of laboratory samples of high-capacity centrifugal precision laboratory instruments.
Product features:
1, outstanding performance: micro-computer control, frequency control DC, brushless DC motor without carbon powder pollution;
2, simple: touch panel, digital display, intuitive and reliable;
3, high-capacity multi-rotor, the user easily select

Technical data:
Maximum speed: 5000r/min
No. 1 rotor: 2 *400ml
No. 2 rotor: 4 * 250ml
No. 3 rotor: 36 * 10ml
No. 4 rotor: 72 * 5ml
Motor: Brushless DC Motor
Timing range: 0-99min


Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
1.Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
2.Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
3.Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 Degrees -60 Degrees) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
4.Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
5. To ensure safety, be sure to use ground wire
6.In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
7.Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish.Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
8. Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
9. Centrifugal liquid should not be too low boiling point,Should pay attention to internal

 相關(guān)同類產(chǎn)品:

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

上海碩光電子科技有限公司 版權(quán)所有

ICP備案號(hào):滬ICP備14032911號(hào)-5 管理登陸 技術(shù)支持:化工儀器網(wǎng)   總流量:477678  sitemap.xml

在線客服
  • 劉先生

    021-65682142

    13816422470

在線客服
用心服務(wù) 成就你我
色94色欧美sute亚洲线路二| 51精品国产人成在线观看| 少妇荡乳情欲办公室456视频| 日产精品一卡2卡三卡4乱码| 中文字幕一区二区| 日韩在线一区二区三区免费视频 | 欧美成人成人a片在线乱码视频| 波多野结衣52部合集在线观看| 久久久亚洲av波多野结衣| 国产成人精品亚洲日本在线观看| 97资源超碰在线视频| 人妻小慧办公室沉伦全文番外篇 | 亚洲日产乱码一二三区别| 久久久久久精品国产亚洲| 最新毛片婷婷99精品视频| 麻豆国产精品番甜甜七夕| 换人妻好紧4p| 少妇高潮尖叫声久久a片| 大香伊人久久精品一区二区| 久久久无码精品亚洲日韩精东传媒| 亚洲加勒比久久88色综合| 无码人妻精品一区二区三区东京热| 国产精品久久久久无码av| 国产婷婷一区二区三区| 亚洲精品乱码久久久久久| 久久久噜噜噜久久中文字幕色伊伊 | 欧美性潮喷xxxxx免费视频看| 国产日产成人免费视频在线观看| 男人亚洲成色av网站| 1313久久国产午夜精品理论片 | 欧美亚洲日韩国产区一| 秘书在办公室被躁bd在线观看 | summertime在线播放| 隔壁人妻偷人bd中字| 青娱乐极品盛宴| 日韩av片无码一区二区不卡| 福利一区二区三区视频在线观看| 精品国产乱码久久久EA7| 高清欧美性猛交xxxx黑人猛交 | 屁屁草草影院ccyycom| 极品少妇被猛的白浆直喷白浆 |